Specifi cations
LED indication for supply and data-
Power supply: 12...18VDC-
Consumption: 30mA standby, 150mA max-
250 possible addresses -
Standard DIN-rail housing : 2 modules-
Dimensions: 90 x 36 x 58mm / 3.5 x 1.4 x 2.3”-
Features :
contacts may be placed at a long distance from the module-
local buttons and LED indication per input-
different reaction times can be set for each input: 0, 1, 2 or 3 seconds-
complete confi guration via Velbus PC interface (e.g.- VMB1USB, VMBRSUSB) and VELBUSLINK
detects long or short press to activate second channel-
multi-channel possibility, each short press activates next channel-
extended day, week and year timers with possible sun (rise/set) synchronisation-
connect one of our kWh counters (- EMDIN01, EMDIN02 or EMDIN03) and monitor your instant power consuption using;
Velbuslink or one of our operation panels VMBLCDWB, VMBLCDBB, VMBGPOW, VMBGPOB.
Connect any type of sensor or switch (distance is not an issue) and you can control anything. E.g. connect the motion detector of your driveway and switch on
the garden lighting for 2 minutes… The module has very extended timer functions.
The fi rst 4 inputs can be used as counter inputs for conection of kWh counter, then the instant power consumption can be measured.